To get a PDF copy, press Print and choose “Save as PDF”.

FRP Trapezoidal Sheet Technical Data Sheet — GFRP Trapezoidal Rooflight for Industrial Buildings by NABAK COMPOSITE

Cover of the NABAK COMPOSITE trapezoidal fiberglass sheet technical data sheet – FRP / GRP Trapezoidal Sheet, code NBK-TDS-TRS-01-EN
FRP / GFRP Trapezoidal Fiberglass Sheet — Technical Data SheetIntroduction, structure and benefits | Page 1 of 5

NABAK COMPOSITE trapezoidal fiberglass sheet (FRP / GRP Trapezoidal Sheet) is a translucent ribbed GFRP composite sheet produced to exactly match the trapezoidal metal sheets of industrial buildings. Used as roof and wall rooflights in industrial buildings, warehouses, factories and sports halls, it brings daylight in without glare and, alongside galvanized or pre-painted sheet, creates a continuous, corrosion-resistant roof.

3 – 8Ribs per metre width
20 – 45 mmRib height
≤ 1450 mmPurlin spacing
U ≈ 3.0Double-skin rooflight (W/m²K)

What is trapezoidal fiberglass sheet (trapezoidal FRP sheet)?

Trapezoidal fiberglass sheet, also known as trapezoidal GRP sheet, trapezoidal FRP sheet, trapezoidal composite sheet, trapezoidal rooflight, industrial rooflight and ribbed fiberglass sheet, is made from glass-fibre mat and unsaturated polyester resin by continuous lamination and is cured in forming moulds into a profile with flat crowns (ribs), inclined webs and wide pans. FRP is the general name for fibre-reinforced polymers, and GFRP (or GRP) is FRP made with glass fibre.

The main difference between trapezoidal and corrugated fiberglass sheet is its ribbed geometry: tall webs and flat crowns increase the moment of inertia for the same weight and allow longer purlin spacing. More importantly, trapezoidal GFRP sheet has the same profile as the metal roof sheet and sits over it at the side lap without gaps or leaks — which is why it is the standard rooflight for metal-clad buildings.

Layered structure of trapezoidal composite sheet

Outer UV-protective layerUV-stabilising film or gelcoat that prevents yellowing, dulling and fibre blooming.
GFRP laminateGlass-fibre mat at 25 to 35% by weight in polyester resin; the load-bearing, light-diffusing element.
Smooth inner layerSmooth, glossy inner surface that stays clean and reflects light better into the space.
Second skin (optional)A second sheet on spacers for an insulated double-skin rooflight that prevents condensation.

Benefits of trapezoidal fiberglass sheet

  • Same profile as metal sheet: a rooflight strip continuous with galvanized, pre-painted sheet or sandwich panels; no change to the building frame.
  • High stiffness: tall ribs keep trapezoidal FRP sheet stable at typical industrial purlin spacings (1 to 1.4 m).
  • Diffused daylight: lower lighting electricity use during the day, without harsh shadows or glare.
  • Corrosion-resistant: composite sheet does not rust in chemical fumes, ammonia, humidity or salt — unlike the metal sheet beside it.
  • Low expansion: thermal expansion about half that of polycarbonate; better compatibility with steel sheet and fasteners.
  • Insulated double-skin version: double-skin trapezoidal rooflight with U ≈ 3 W/m²K for heated buildings.

Applications of trapezoidal fiberglass sheet

Industrial building rooflightsFRP rooflight strips between galvanized and pre-painted sheets
Warehouses and logistics centresLower daytime lighting energy with trapezoidal GFRP rooflights
Buildings with sandwich panelsDouble-skin trapezoidal rooflights matching the sandwich-panel skin
Chemical and fertiliser plantsTrapezoidal composite sheet resistant to corrosive fumes
Industrial poultry and livestock housesRooflights resistant to ammonia and humidity
Sports halls and industrial facadesWall rooflight strips with trapezoidal fiberglass sheet
FRP / GFRP Trapezoidal Fiberglass Sheet — Technical Data SheetProfiles, sizes, weight and types | Page 2 of 5

Profiles of trapezoidal fiberglass sheet

Table 1 — Geometry of common trapezoidal FRP sheet profiles (cover width 1000 mm)
Profile codeRib pitch p (mm)Rib height h (mm)Crown width (mm)Pan width (mm)Ribs per cover widthDistributed-load coefficient kApplication
NBK-T20/12512520306581.16Building walls, canopies
NBK-T35/200200354011051.18Standard industrial rooflights
NBK-T40/250250405014041.16Industrial roofs, warehouses
NBK-T45/333333456021331.15Long-span purlin roofs, sandwich panels

Profile codes are indicative. Trapezoidal fiberglass sheet is always produced to the project’s metal-sheet profile (pitch, height, crown and pan width and number of ribs); to order, send a sample or a section drawing of the metal sheet. The k factor is calculated with Formula 2 (page 4).

Thickness and weight of trapezoidal composite sheet

Table 2 — Areal weight of trapezoidal GFRP sheet by thickness (ρ = 1.45 g/cm³)
Thickness (mm)Flat sheet weight (g/m²)T20/125 (kg/m²)T35/200 (kg/m²)T40/250 (kg/m²)T45/333 (kg/m²)
1.014501.681.711.681.66
1.217402.022.052.021.99
1.521752.522.572.522.49
2.029003.363.423.363.32

Trapezoidal fiberglass sheet length is made to order, up to 12 m in one piece. For roofs where foot traffic is possible, a heavier sheet (≥ 2.4 kg/m²) and a roof fragility assessment (ACR[M]001 method) are recommended.

Trapezoidal rooflight types and colours

Table 3 — Trapezoidal fiberglass sheet options (1.2 mm per skin)
TypeVisible light transmissionU value (W/m²K)Recommended use
Single-skin clear75 – 85%≈ 6.9Unheated warehouses and buildings, canopies
Single-skin opal50 – 65%≈ 6.9Production halls with soft light, reduced radiant heat
Single-skin coloured (blue, green)35 – 60%≈ 6.9Matching metal-sheet colour, canopies
Double-skin with spacers60 – 70%≈ 3.0Heated buildings, with sandwich panels
Triple-skin45 – 55%≈ 1.9Cold stores, halls with energy requirements

Trapezoidal fiberglass sheet is supplied in clear, opal, blue and green and in custom colours matching the metal sheet. U values are calculated with Formula 6 (page 5).

Ordering a matching profile: the smallest difference in rib pitch or height causes leaks at the side lap. To order trapezoidal fiberglass sheet, send a 30 cm piece of the project’s metal sheet or an accurate section drawing (pitch, height, crown and pan width, number of ribs and overlap edge type) so the rooflight mould is set to exactly the same size.

FRP / GFRP Trapezoidal Fiberglass Sheet — Technical Data SheetProperties, comparison and standards | Page 3 of 5

Mechanical and physical properties of trapezoidal FRP sheet

Table 4 — Reference properties of the GFRP laminate in trapezoidal fiberglass sheet
PropertyTest standardUnitTypical value
Glass fibre content (by weight)ASTM D2584%25 – 35
DensityASTM D792g/cm³1.4 – 1.5
Tensile strengthASTM D638MPa70 – 110
Flexural strengthASTM D790MPa120 – 180
Flexural modulusASTM D790GPa5 – 7
Coefficient of thermal expansionASTM D69610⁻⁶ /°C25 – 35
Thermal conductivity—W/m·K0.18 – 0.25
Solar energy transmittance g (clear / opal)EN 410—0.75 – 0.80 / 0.55 – 0.65
Service temperature range—°C−40 to +90

The g value is the ratio of total solar energy transmitted through the sheet (solar heat gain coefficient). Values are common reference ranges of the FRP and GFRP composites industry and are not NABAK COMPOSITE’s own laboratory results.

Trapezoidal fiberglass rooflight compared with other options

Table 5 — Trapezoidal FRP sheet vs trapezoidal polycarbonate and metal roof sheet
FeatureTrapezoidal fiberglass sheetTrapezoidal polycarbonateGalvanized steel sheet
Light transmission50 – 85%, diffusedUp to 90%, clear and directZero
Expansion coefficient (10⁻⁶ /°C)25 – 3565 – 7012
Relative movement against steel sheet over 6 m at ΔT = 50 °C≈ 4 – 7 mm≈ 16 – 17 mm—
Resistance to chemical fumes and ammoniaExcellentPoorCorrosion
Stability under high roof temperaturesGood (up to ≈ 90 °C)GoodExcellent
Profile match with metal sheetComplete (to order)Limited profiles—

Reference standards for trapezoidal fiberglass sheet

Table 6 — Common standards and tests for composite rooflights
TopicReference standardRelevance to trapezoidal GFRP sheet
Single-skin profiled rooflight sheetsEN 1013Dimensional, mechanical, optical and durability requirements for FRP sheet
Rooflights with metal-sheet profilesEN 14963Continuous rooflights and compatibility with roof cladding
Glass-fibre-reinforced polyester sheetASTM D3841Classification of light transmission, weathering and fire
Roof performance under external fireEN 13501-5 / BS 476-3Broof class for the fire-retardant grade
Roof fragilityACR[M]001Safety assessment against falls through rooflights

Trapezoidal or corrugated? If the building roof is clad with trapezoidal metal sheet or sandwich panels, the rooflight must be trapezoidal fiberglass sheet of the same profile. Corrugated fiberglass sheet suits roofs with corrugated sheets, greenhouses and canopies better. Trapezoidal sheet is stiffer for the same weight and spans further between purlins.

FRP / GFRP Trapezoidal Fiberglass Sheet — Technical Data SheetRibbed-section and purlin-spacing formulas | Page 4 of 5

Thin-walled section formulas for trapezoidal sheet

1. Horizontal width of the inclined web
w = p − a − b2 ,   lw = √( w² + h² )

a crown width, b pan width. T35/200: w = (200 − 40 − 110)/2 = 25 mm and lw ≈ 43 mm

2. Developed-length factor of a ribbed profile
k = a + b + 2 lwp

T35/200: (40 + 110 + 2 × 43.0) / 200 ≈ 1.18; areal weight ws = ρ · t · k

3. Moment of inertia of a thin-walled section (line-element method)
ȳ = Σ li yiΣ li ,   I = Σ t li ( Δyi²12 + (yi − ȳ)² ) ,   Iw = I · 1000p

li length of each element (crown, web, pan), yi height of its centre, Δyi height difference between its two ends. T35/200 with t = 1.2: Iw ≈ 2.90×10⁵ mm⁴/m. In wide pans, local buckling reduces the effective width; Table 7 covers this effect with a conservative stress limit.

4. Sheet deflection between purlins
δ = 5 q L⁴384 E Iw ≤ L150

E ≈ 6 GPa, q snow load or wind suction (N/mm per metre width)

5. Bending stress in crown or pan
σ = q L² · c8 Iw ≤ σu3

c = max(ȳ, h − ȳ) distance to the extreme fibre, σu ≈ 130 MPa

Purlin spacing table for trapezoidal fiberglass sheet

Table 7 — Maximum purlin spacing (mm) on two supports, deflection limit L/150 and stress σu/3
Profile / thicknessLoad 0.75 kPaLoad 1.0 kPaLoad 1.5 kPa
T20/125 — 1.2 mm740670580
T20/125 — 1.5 mm790720630
T35/200 — 1.2 mm1050960840
T35/200 — 1.5 mm11401030900
T40/250 — 1.5 mm12401120980
T45/333 — 1.5 mm132012001040
T45/333 — 2.0 mm145013201150

Calculated with Formulas 3 to 5 and E = 6 GPa. The table is a calculation example; a sheet continuous over several purlins may span further, and in snowy regions the snow load of Part 6 of the Iranian National Building Regulations determines the table column. If the building’s purlin spacing exceeds the table, a thicker sheet or an auxiliary purlin under the rooflight strip is recommended.

Full example — T35/200 rooflight, 1.2 mm thick, on purlins at 1000 mm under 1 kPa: Iw ≈ 2.90×10⁵ mm⁴/m ; q = 1.0 N/mm (per m width) δ = 5 × 1.0 × 1000⁴ / (384 × 6000 × 2.90×10⁵) ≈ 7.5 mm ≤ L/150 = 6.7 mm ✗ → L = 960 mm: δ ≈ 6.35 mm ≤ L/150 = 6.4 mm ✓ (matches Table 7) In this case either a 1.5 mm sheet (purlins up to 1030 mm) is chosen or the purlin spacing under the rooflight strip is reduced slightly.
FRP / GFRP Trapezoidal Fiberglass Sheet — Technical Data SheetThermal insulation, condensation and installation | Page 5 of 5

Thermal and condensation-control formulas for industrial rooflights

6. Thermal transmittance of the rooflight
U = 1Rsi + Σ ti/λ + Σ Rair + Rse

Rsi = 0.10, Rse = 0.04, λ ≈ 0.20, Rair ≈ 0.18 m²K/W. Single-skin ≈ 6.9; double-skin ≈ 3.0; triple-skin ≈ 1.9 W/m²K

7. Inner surface temperature of the sheet
Tsi = Ti − U · Rsi · ( Ti − To )

Ti = 20 °C, To = 0 °C: single-skin Tsi ≈ 6.3 °C; double-skin ≈ 14.0 °C; triple-skin ≈ 16.1 °C

8. Dew point of indoor air (Magnus formula)
γ = ln(RH/100) + 17.27 T237.7 + T ,   Td = 237.7 γ17.27 − γ

20 °C and 60% humidity → Td ≈ 12.0 °C. Because single-skin Tsi (6.3) is below Td, condensation occurs; double-skin (14.0) is condensation-free.

9. Heat loss through the rooflight strip
Q = U · A · ΔT

100 m² of rooflight, ΔT = 20 °C: single-skin ≈ 13.7 kW; double-skin ≈ 6.0 kW; saving ≈ 56% with a double-skin trapezoidal rooflight

10. Daylight factor of the building
DF = EinEout × 100 ≈ τ · AsAf · η × 100

Typical target DF = 2 to 5%. τ = 0.70, η = 0.6, rooflights 8% of roof → DF ≈ 3.4%

11. Relative movement of rooflight and steel sheet
ΔLrel = ( αFRP − αst ) · L · ΔT

6 m sheet, αFRP = 30×10⁻⁶, αst = 12×10⁻⁶, ΔT = 50 °C → ≈ 5.4 mm; screw holes 3 to 4 mm larger than the screw diameter

Installation details for trapezoidal fiberglass sheet

  1. Rooflight layout: place FRP sheets in regular strips between metal sheets; keep rooflights at least one purlin away from the eaves and ridge.
  2. Side lap: lay the fiberglass sheet over the downstream metal sheet and under the upstream metal sheet, with a full-rib overlap and butyl tape.
  3. End lap: at pitches ≥ 10°, 150 mm overlap; at 5 to 10° pitch, 250 mm with two rows of sealing tape.
  4. Fixing: on roofs fix through the rib crown with self-drilling screws, metal-EPDM washers and spacer bushes so the rib is not crushed; on walls fix in the pan.
  5. Double skin: fit composite or insulating spacers between the two skins and close the edges with profiled foam fillers.
  6. Safety: do not walk on rooflights; provide access routes with boards across the purlins and, where needed, safety mesh under the rooflight.

Do fiberglass rooflights make the building hotter?

Clear sheet has a g value of about 0.75; for buildings in hot climates, opal rooflights with g of about 0.6 or a rooflight area below 10% of the roof are recommended.

Why do water droplets collect under industrial rooflights?

This is condensation: the inner surface temperature of a single-skin rooflight is below the dew point (Formulas 7 and 8). A double-skin rooflight and building ventilation solve the problem.

Request a quote for trapezoidal fiberglass sheet: send the metal-sheet profile drawing or sample, thickness, single or double skin, colour, length and number of sheets, purlin spacing and building type.
Nabak Saze Gostar | nabakcomposite.com | +98 21 4881 2124 | Mobile +98 912 396 3078 | Instagram @nabak.composite

Disclaimer: The information in this data sheet is based on general, typical data of the FRP and GFRP composites industry and is intended as guidance only. NABAK COMPOSITE reserves the right to change the technical specifications of trapezoidal fiberglass sheet without notice.