To get a PDF copy, press Print and choose “Save as PDF”.

FRP I-Beam Technical Data Sheet — GFRP Structural Beam and Fiberglass Beam by NABAK COMPOSITE

Cover of the NABAK COMPOSITE FRP I-beam technical data sheet – FRP / GRP I-Beam Profile, code NBK-TDS-IBE-01-EN
FRP I-Beam (I-Section) — Technical Data SheetIntroduction, types and applications | Page 1 of 5

NABAK COMPOSITE FRP I-beam (FRP / GRP I-Beam) is a pultruded I-shaped GFRP profile with two flanges and one web. It is the main structural member of composite structures and replaces steel I-beams as beams and columns of platforms, footbridges, cooling towers, marine structures and chemical plants — at a quarter of the weight, rust-free, electrically insulating and paint-free.

76 – 305 mmComposite beam depth
≥ 23 GPaLongitudinal modulus of elasticity
≥ 240 MPaLongitudinal flexural strength (E23)
≈ 1/4of the weight of an equal steel I-beam

What is an FRP I-beam?

Composite beam, also known as composite I-beam, FRP I-beam, GFRP beam, fiberglass beam, composite structural beam and composite I-profile, is made by pultruding continuous glass-fibre rovings and transverse mats impregnated with resin through a heated I-shaped die. Dense longitudinal fibres are placed in the flanges for maximum bending stiffness and strength, while mats and multi-directional fabrics in the web provide shear strength and bolt bearing.

FRP is the general name for fibre-reinforced polymers, and GFRP (or GRP) is FRP made with glass fibre. The doubly symmetric section of a composite I-beam puts the shear centre at the centroid, so, unlike channels and angles, load on the beam axis causes no torsion — making the FRP I-beam the most efficient composite profile for bending.

NABAK COMPOSITE beam types

I-beam (narrow flange)Flange width about half the depth; the highest bending stiffness for the weight; platform and bridge beams.
Wide-flange WF beamFlange width equal to depth; higher weak-axis stiffness; columns and unbraced beams.
ResinsIsophthalic for general use, vinyl ester for chemical environments, fire-retardant resin for public spaces.
Colour and surfaceYellow, grey, green and custom colours with a UV-resistant veil over the whole surface of the GFRP beam.

Advantages of FRP beams over steel I-beams

  • Corrosion-resistant: composite beams do not rust in seawater, chlorine, acids or sewage; no galvanizing, painting or periodic repair.
  • Lightweight: a 203×102×9.5 composite I-beam weighs only 6.8 kg/m; installed by hand and easily carried to remote locations.
  • Electrically insulating and non-magnetic: safe platforms in substations, battery rooms and near sensitive equipment.
  • High strength-to-weight ratio: the specific strength of GFRP beams is several times that of structural steel.
  • No welding or fire: cut and bolted on site; suited to refineries and areas where hot work is restricted.
  • Long service life: the life-cycle cost of composite beams in corrosive environments is far below steel I-beams.

Applications of FRP composite beams

Industrial platforms and walkwaysBeams and columns of composite grating platforms in petrochemical and treatment plants
Pedestrian bridgesMain beams of lightweight bridges with composite decking
Cooling towersInternal frame of towers with GFRP beams and columns
Marine structuresJetties, coastal platforms and structures in contact with saltwater
Substations and utilitiesInsulating structures and work platforms near live equipment
Chemical industrySupport structures for tanks, pipes and equipment in corrosive fumes
FRP I-Beam (I-Section) — Technical Data SheetSize and section property tables | Page 2 of 5

Composite I-beam table (narrow flange)

Table 1 — FRP I-beam: sizes and section properties (t = flange and web thickness, ρ = 1.85 g/cm³)
Size h×b×t (mm)A (mm²)Weight (kg/m)Ix (mm⁴)Wx (mm³)ix (mm)Iy (mm⁴)iy (mm)J (mm⁴)Cw (mm⁶)
76 × 38 × 6.48911.657.25×10⁵1.91×10⁴28.55.99×10⁴8.21.22×10⁴7.26×10⁷
102 × 51 × 6.412242.261.87×10⁶3.67×10⁴39.11.43×10⁵10.81.67×10⁴3.28×10⁸
152 × 76 × 6.418643.456.60×10⁶8.68×10⁴59.54.71×10⁵15.92.54×10⁴2.50×10⁹
152 × 76 × 9.527085.019.20×10⁶1.21×10⁵58.37.05×10⁵16.18.15×10⁴3.58×10⁹
203 × 102 × 9.536866.822.31×10⁷2.27×10⁵79.11.69×10⁶21.41.11×10⁵1.59×10¹⁰
254 × 127 × 12.7612911.345.96×10⁷4.70×10⁵98.64.37×10⁶26.73.30×10⁵6.37×10¹⁰
305 × 152 × 12.7741213.711.06×10⁸6.93×10⁵119.47.48×10⁶31.83.98×10⁵1.60×10¹¹

Composite wide-flange (WF) beam table

Table 2 — FRP WF beam: sizes and section properties
Size h×b×t (mm)A (mm²)Weight (kg/m)Ix (mm⁴)Wx (mm³)ix (mm)Iy (mm⁴)iy (mm)J (mm⁴)Cw (mm⁶)
102 × 102 × 6.418763.473.37×10⁶6.60×10⁴42.41.13×10⁶24.62.56×10⁴2.59×10⁹
152 × 152 × 9.541527.681.65×10⁷2.18×10⁵63.15.57×10⁶36.61.25×10⁵2.83×10¹⁰
203 × 203 × 9.5560510.374.11×10⁷4.05×10⁵85.61.33×10⁷48.61.69×10⁵1.24×10¹¹
254 × 254 × 12.7935517.311.07×10⁸8.40×10⁵106.83.47×10⁷60.95.03×10⁵5.05×10¹¹

Properties are calculated with Formulas 1 to 5 (page 4) for sharp corners. Sizes are based on common imperial sizes of pultruded profiles (3 to 12 inches). Standard length is 6 m; lengths up to 12 m and cutting and drilling to drawing can be ordered. Tolerances per EN 13706-2.

I-beam or WF? For bending members whose compression flange is restrained by grating or decking, the narrow-flange composite I-beam is stiffer for the same weight. For columns and beams without lateral restraint, the wide-flange WF beam is the better choice thanks to its three to five times higher Iy; however, its wide, thin flanges are more sensitive to local buckling (Formula 8).

Selection guide for composite beams

Table 3 — Recommended FRP beam for common applications
ApplicationRecommended composite beam (mm)Design note
Grating platform joist (span 1 – 1.5 m)I 102×51×6.4 / I 152×76×6.4Bolt grating to the flange (continuous restraint)
Main platform beam (span 2 – 3 m)I 203×102×9.5 / I 254×127×12.7Check deflection with Table 5 (page 3)
Footbridge beam (span 3 – 5 m)I 305×152×12.7 or double beamCheck deflection, vibration and concentrated loads
Platform column (height 2 – 3 m)WF 152×152×9.5 / WF 203×203×9.5Weak-axis and local buckling (Formulas 8 and 9)
Cantilever beam and pipe supportWF 102×102×6.4 / I 152×76×9.5Lateral restraint at the free end
Light roof and canopy beamI 102×51×6.4 / I 152×76×6.4Purlins or roof sheet restrain the flange
FRP I-Beam (I-Section) — Technical Data SheetProperties, allowable load tables and comparison | Page 3 of 5

Mechanical properties of composite beams

Table 4 — Reference properties of GFRP I-beam (based on EN 13706 grade E23)
PropertyEN 13706 grade E23 minimumTypical value, FRP beamRole in design
Longitudinal modulus EL (flange)23 GPa23 – 28 GPaBending deflection and buckling
Shear modulus GLT (web)—3 – 4 GPaShear deflection, lateral-torsional and local buckling
Longitudinal flexural / tensile strength240 MPa250 – 350 MPaSection strength
Longitudinal compressive strength—240 – 300 MPaColumns and compression flange
In-plane shear strength of the web25 MPa (apparent)40 – 60 MPaWeb shear at supports
Transverse compressive strength—70 – 120 MPaWeb crushing under concentrated load
Pin-bearing strength, longitudinal / transverse150 / 70 MPa180 – 220 / 90 – 120 MPaBolted connections

Allowable load table of composite beams by span

Table 5 — Allowable uniform load (kN/m) of a simply supported composite I-beam with continuous lateral restraint; deflection limit L/250 (bending + shear) and FS = 2.5
I-beam (mm)L = 1.5 mL = 2.0 mL = 3.0 mL = 4.0 mL = 5.0 m
102 × 51 × 6.43.541.560.480.20—
152 × 76 × 6.410.55.131.630.700.36
152 × 76 × 9.515.67.172.270.980.51
203 × 102 × 9.533.716.45.452.401.26
254 × 127 × 12.774.738.213.46.023.18
305 × 152 × 12.782.546.420.610.35.49

Values are the lesser of the deflection case (Formula 6) and the stress case with stress limit min(σu, σfl) / 2.5, where σfl is the lower bound of flange local buckling (Formula 8). Loads exclude beam self-weight and concentrated loads. Calculated with E = 23 GPa and G = 3 GPa as a design example; final design should follow ASCE/SEI 74. Without lateral restraint the allowable load drops sharply (Formula 7).

Table 6 — Allowable concentrated load at midspan (kN), continuous lateral restraint, L/250 and FS = 2.5
I-beam (mm)L = 1.5 mL = 2.0 mL = 3.0 m
152 × 76 × 6.47.885.913.01
203 × 102 × 9.525.318.99.98
254 × 127 × 12.760.144.724.2
305 × 152 × 12.761.946.431.0

Composite beam compared with steel I-beam

Table 7 — Composite I-beam 203×102×9.5 vs steel IPE 200
FeatureGFRP beam 203×102×9.5Steel IPE 200
Weight (kg/m)6.822.4
Ix (mm⁴) / stiffness EI (kN·m²)2.31×10⁷ / ≈ 5311.94×10⁷ / ≈ 4080
Corrosion in marine and chemical environmentsNoneSevere
Electrical conductivityInsulatingConductive
Governing design criterionDeflection and bucklingStrength
FRP I-Beam (I-Section) — Technical Data SheetSection and deflection formulas | Page 4 of 5

Section property formulas for composite I-beams

1. Cross-section area and weight
A = 2 b tf + hw tw ,   hw = h − 2tf

203×102×9.5: A = 2 × 102 × 9.5 + 184 × 9.5 ≈ 3686 mm²; w = 1.85 × 3686 × 10⁻³ ≈ 6.82 kg/m

2. Moment of inertia and section modulus, strong axis
Ix = b h³ − (b − tw) hw³12 ,   Wx = 2Ixh

203×102×9.5: Ix ≈ 2.31×10⁷ mm⁴, Wx ≈ 2.27×10⁵ mm³

3. Weak-axis moment of inertia
Iy = 2 tf b³ + hw tw³12 ,   i = √(I/A)

203×102×9.5: Iy ≈ 1.69×10⁶ mm⁴, iy ≈ 21.4 mm

4. Torsion constant and warping constant
J = 2 b tf³ + hw tw³3 ,   Cw ≈ Iy (h − tf)²4

203×102×9.5: J ≈ 1.11×10⁵ mm⁴, Cw ≈ 1.59×10¹⁰ mm⁶

5. Web shear area
Aw = hw · tw ,   τ = VAw ≤ τuFS

152×76×6.4: Aw = 139.2 × 6.4 ≈ 891 mm². In a composite beam the web carries almost all the shear, and its contribution to shear deflection is significant.

Deflection of composite beams (Timoshenko theory)

6. Total deflection of a simply supported beam under uniform load
δ = 5 q L⁴384 EL Ix + q L²8 k GLT Aw ≤ L250
Example — composite I-beam 152×76×6.4, span 3 m, uniform load 1.5 kN/m, continuous lateral restraint (k = 1): δb = 5 × 1.5 × 3000⁴ / (384 × 23 000 × 6.60×10⁶) ≈ 10.4 mm δs = 1.5 × 3000² / (8 × 3000 × 891) ≈ 0.63 mm → δ ≈ 11.1 mm ≤ 12.0 mm ✓ σ = qL²/(8Wx) = 1.5 × 3000² / (8 × 8.68×10⁴) ≈ 19.4 MPa ≪ 85 / 2.5 = 34 MPa ✓ The FRP beam stress is far below the allowable value and deflection governs the design — the defining feature of all composite beams. Shear deflection accounts for about 6% at this span and more at shorter spans.

Increasing composite beam stiffness: since deflection is controlled by E·I and the composite E is fixed, the most effective approach is a deeper beam (I grows with the cube of depth). Replacing a 152 mm beam with a 203 mm beam increases stiffness 3.5 times while only doubling the weight. Continuous fixing of composite decking to the top flange also increases stiffness through composite action.

FRP I-Beam (I-Section) — Technical Data SheetBuckling, columns, connections and fabrication | Page 5 of 5

Buckling of composite beams and columns

7. Lateral-torsional buckling of an I-beam
Mcr = Cb πLb √( E Iy G J + ( π ELb )² Iy Cw )

Cb moment-gradient factor (1 for uniform moment, ≈ 1.14 for uniform load). Beam 152×76×6.4 with Cb = 1: Lb = 3 m → Mcr ≈ 1.29 kN·m; Lb = 1 m → Mcr ≈ 8.3 kN·m. Section capacity limited by flange local buckling is ≈ 7.4 kN·m, so lateral restraint every metre unlocks the full capacity of the composite beam.

8. Local buckling of the compression flange (lower bound)
σfl ≈ GLT · ( tfb/2 )²

Free flange edge with a pinned support at the web; conservative, since the web partly restrains the flange. 152×76×6.4 → ≈ 85 MPa; 203×203×9.5 (WF) → ≈ 26 MPa. Detailed calculation per ASCE/SEI 74.

9. Column buckling about the weak axis
Pcr = π² E Iy(K L)² ,   Pa = min(Pcr, σfl A, σc A)FS

WF column 152×152×9.5, 3 m long, pinned both ends: Pcr ≈ 140 kN, σfl A ≈ 195 kN → Pa ≈ 140 / 2.5 ≈ 56 kN

10. Bolted web connection capacity (clip angles)
Pbr = n d tw σbrFS ;   e1 ≥ 2d, p ≥ 4d

4 M12 bolts in a 9.5 mm web, σbr = 150 MPa, FS = 3: Pbr = 4 × 12 × 9.5 × 150 / 3 ≈ 22.8 kN

11. Web crushing at supports
Ra = σc,T · tw · (N + 2.5 tf)FS

203×102×9.5, N = 100 mm, σc,T ≈ 70 MPa, FS = 3: Ra ≈ 27.4 kN; for higher loads install a web stiffener (FRP angle or plate).

Installation guide for composite beams

  1. Lateral restraint: restrain the compression flange of FRP beams with grating, decking or cross joists at spacing ≤ 1 m.
  2. Connections: use double composite clip angles on the web with stainless or FRP bolts and wide washers.
  3. Stiffeners: install bonded and bolted composite web stiffeners under concentrated loads and over supports.
  4. Cutting and drilling: use diamond or carbide saws and drills; seal cut surfaces with compatible resin.
  5. Bearing: beam bearing length on supports at least 100 mm, with no sharp-edge contact.
  6. Sustained load: for large permanent loads, account for composite creep (deflection increase over time) in design.
Request a quote for FRP composite beams: send section type (I or WF) and size, length and number of bars, span and load, colour, resin type and the cutting and drilling drawing.
Nabak Saze Gostar | nabakcomposite.com | +98 21 4881 2124 | Mobile +98 912 396 3078 | Instagram @nabak.composite

Disclaimer: The information in this data sheet is based on general, typical data of the FRP and GFRP composites industry and the EN 13706 standard, and is intended as guidance only. Examples and load tables are for illustration; structural design must be carried out by an engineer to ASCE/SEI 74 or CEN/TS 19101. NABAK COMPOSITE reserves the right to change technical specifications without notice.