FRP / GFRP Channel Profile — Technical Data SheetIntroduction, structure and applications | Page 1 of 5

NABAK COMPOSITE FRP channel (FRP / GRP Channel Profile) is a pultruded C-shaped GFRP profile with one web and two flanges. Lightweight, rust-free, electrically insulating and paint-free, it replaces UNP and galvanized steel channel in joists, purlins, platform frames, cable-tray supports, stairs and light structures in corrosive environments.

50 – 300 mmChannel web height
≥ 240 MPaLongitudinal tensile strength (E23)
≥ 23 GPaLongitudinal modulus of elasticity
≈ 1/4of the weight of an equal steel channel

What is FRP channel (GFRP channel profile)?

Composite channel, also known as FRP channel, GFRP channel, fiberglass channel, composite channel profile, composite C and U profile and pultruded channel, is made by pultruding continuous glass-fibre rovings and transverse mats impregnated with resin through a heated C-shaped die. Longitudinal fibres in the web and flanges provide the bending stiffness and strength of the channel beam, while transverse mats increase shear strength, bolt bearing and corner integrity.

FRP is the general name for fibre-reinforced polymers, and GFRP (or GRP) is FRP made with glass fibre. Composite channel is an open, singly symmetric section; its shear centre lies outside the web, and load applied to the web tends to twist the beam. Lateral restraint, the point of load application and the use of double channels are therefore especially important in the design of FRP channel beams (pages 4 and 5).

Parts and structure of composite channel

WebThe main shear element and source of section depth; where the channel is bolted to columns and beams.
FlangesTwo parallel flanges carrying most of the moment of inertia and bending strength.
Inside cornersCorner radius with continuous fibres to reduce stress concentration between web and flange.
Surface veilResin-rich surface for UV and chemical resistance of GFRP channel.

Advantages of FRP channel over steel channel

  • Corrosion-resistant: composite channel does not rust in seawater, chlorine, acids or sewage; no galvanizing or painting.
  • Lightweight: a 152×42×6.4 GFRP channel weighs only 2.6 kg/m; installed by hand without a crane.
  • Insulating and non-magnetic: suited to substations, cable trays and sensitive equipment.
  • Flat faces for connections: the flat web and flanges of FRP channel allow simple bolting to columns, grating and decking.
  • No welding or hot work: cut with a diamond saw and joined with bolts and structural adhesive.
  • Flexible combinations: double channels, channel with angle and channel with tube create complete composite structures.

Applications of FRP composite channel

Joists and platform framesJoists under composite grating and framing of industrial platforms
Stair stringersStringers for composite stairs with FRP grating treads
Cable tray and railsBrackets, posts and rails supporting cable trays in electrical installations
Purlins and light roofsCanopy purlins, light cladding and roofs in corrosive environments
Cooling towersInternal beams and bracing of towers in GFRP channel
Double channelsSymmetric columns and beams from two back-to-back channels
FRP / GFRP Channel Profile — Technical Data SheetSize and section property tables | Page 2 of 5

Size and weight table of composite channel

Table 1 — FRP channel: sizes, weight and properties about the strong x-axis (ρ = 1.85 g/cm³)
Size h×b×t (mm)A (mm²)Weight (kg/m)Ix (mm⁴)Wx (mm³)ix (mm)
50 × 25 × 43680.681.31×10⁵5.23×10³18.9
76 × 22 × 4.85300.983.85×10⁵1.01×10⁴27.0
100 × 30 × 57501.399.81×10⁵1.96×10⁴36.2
102 × 35 × 6.410191.881.40×10⁶2.75×10⁴37.1
120 × 40 × 611282.092.19×10⁶3.65×10⁴44.1
152 × 42 × 6.414282.644.29×10⁶5.64×10⁴54.8
152 × 42 × 9.520623.815.92×10⁶7.79×10⁴53.6
200 × 55 × 9.527645.111.42×10⁷1.42×10⁵71.6
254 × 70 × 12.746818.663.85×10⁷3.04×10⁵90.7
300 × 90 × 15675012.497.95×10⁷5.30×10⁵108.5

Weak-axis, torsional and shear-centre properties

Table 2 — FRP channel: properties about the weak y-axis and torsional properties
Size h×b×t (mm)x̄ centroid (mm)Iy (mm⁴)iy (mm)J (mm⁴)e0 shear centre (mm)Cw (mm⁶)
50 × 25 × 47.72.07×10⁴7.51.96×10³8.67.51×10⁶
76 × 22 × 4.85.81.85×10⁴5.94.07×10³6.11.63×10⁷
100 × 30 × 57.55.16×10⁴8.36.25×10³8.78.20×10⁷
102 × 35 × 6.49.59.90×10⁴9.91.39×10⁴10.51.57×10⁸
120 × 40 × 610.21.46×10⁵11.41.35×10⁴12.23.32×10⁸
152 × 42 × 6.49.91.88×10⁵11.51.95×10⁴11.97.11×10⁸
152 × 42 × 9.511.02.56×10⁵11.16.20×10⁴11.39.01×10⁸
200 × 55 × 9.513.36.13×10⁵14.98.32×10⁴15.33.94×10⁹
254 × 70 × 12.717.21.67×10⁶18.92.52×10⁵19.41.72×10¹⁰
300 × 90 × 1522.54.18×10⁶24.95.06×10⁵26.15.98×10¹⁰

t is the web and flange thickness (assumed equal); x̄ is the distance of the centroid from the back of the web; e0 is the distance of the shear centre from the web centreline, outward (behind the web). Properties are calculated with the formulas on page 4 for sharp corners. Sizes are common market sizes of pultruded composite channel; standard length 6 m and tolerances per EN 13706-2.

Selection guide for composite channel

Table 3 — Recommended FRP channel for common applications
ApplicationRecommended channel (mm)Design note
Cable-tray rails and brackets50 × 25 × 4 / 76 × 22 × 4.8Web bolted to the column
Platform joist under grating (span 1 – 1.5 m)102 × 35 × 6.4 / 120 × 40 × 6Grating bolted to the flange, continuous lateral restraint
Stair stringer152 × 42 × 6.4 / 200 × 55 × 9.5Treads provide lateral restraint to the stringer
Main platform beam (span 2 – 3 m)200 × 55 × 9.5 / 254 × 70 × 12.7Check deflection and lateral-torsional buckling (Table 6 on page 3)
Light columnDouble 120 × 40 × 6 or 152 × 42 × 6.4Double channel with spacers (Formula 7)
Purlins and canopy frames100 × 30 × 5 / 120 × 40 × 6Roof sheet bolted to the flange
FRP / GFRP Channel Profile — Technical Data SheetMaterial properties, comparison and selection | Page 3 of 5

Mechanical properties of composite channel

Table 4 — Reference properties of pultruded GFRP channel (based on EN 13706 grade E23)
PropertyEN 13706 grade E23 minimumTypical value, FRP channelRelevance to channel design
Longitudinal modulus EL23 GPa23 – 28 GPaBeam deflection and buckling
Shear modulus GLT—3 – 4 GPaShear deflection and lateral-torsional buckling
Longitudinal tensile / flexural strength240 / 240 MPa250 – 350 MPaBeam strength when fully restrained
Transverse tensile / flexural strength50 / 100 MPa50 – 80 / 100 – 130 MPaFlange bending and web-to-flange junction
Transverse compressive strength—70 – 120 MPaWeb crushing under concentrated loads and supports
Apparent shear strength25 MPa25 – 35 MPaWeb shear
Pin-bearing strength, longitudinal / transverse150 / 70 MPa180 – 220 / 90 – 120 MPaBolted web connections
Density / expansion coefficient—1.8 – 1.9 g/cm³ / 8 – 10 ×10⁻⁶Weight and compatibility with steel

Values are typical ranges of the FRP and GFRP composites industry and of EN 13706-3, and are not NABAK COMPOSITE’s own laboratory results. Common design references for pultruded profiles: ASCE/SEI 74 (LRFD design of pultruded FRP structures) and the European CEN/TS 19101.

Composite channel compared with steel channel

Table 5 — FRP channel vs UNP steel and aluminium channel
FeatureGFRP channel 152×42×6.4Steel channel UNP 160Aluminium channel, same size
Weight (kg/m)2.6≈ 18.8≈ 3.9
Modulus E / G (GPa)23 / 3210 / 8170 / 26
Corrosion in marine and chemical environmentsNoneSevereModerate
Electrical conductivityInsulatingConductiveConductive
Sensitivity to lateral-torsional bucklingHigh (restraint needed)LowModerate
Governing beam design criterionBuckling and deflectionStrengthDeflection and strength

Shear centre of a channel: in composite channel the shear centre lies at distance e0 behind the web (Table 2). A load passing through the web or the centroid twists the beam as well as bending it. To avoid torsion, transfer load through a connection on the back of the web near the shear centre, restrain the compression flange, or use back-to-back double channels.

Resin, colour and length of FRP channel

NABAK composite channel is produced with isophthalic polyester resin for general use, vinyl ester for severe chemical environments and fire-retardant resin (ASTM E84 ≤ 25) for public spaces and electrical installations. Common colours are yellow, grey, green, cream and black, with pigment dispersed through the full thickness of the GFRP channel. Standard length is 6 m; lengths up to 12 m and cutting and drilling to drawing can also be ordered.

Effect of unbraced length on channel bending capacity

Table 6 — Ultimate moment of FRP channel (kN·m) by unbraced length of the compression flange (Formula 8, minimum with section strength)
Channel (mm)Section strength σuWxLb = 0.5 mLb = 1.0 mLb = 1.5 mLb = 2.0 m
100 × 30 × 54.72.090.660.370.26
120 × 40 × 68.86.731.961.040.70
152 × 42 × 6.413.510.973.071.571.03
152 × 42 × 9.518.715.274.762.671.86
200 × 55 × 9.534.034.012.616.324.06
254 × 70 × 12.772.872.842.020.4712.80

Values are ultimate and must be divided by a safety factor (e.g. 2.5) for design. Calculated with E = 23 GPa, G = 3 GPa and load at the shear centre; this is an illustrative example and detailed design should follow ASCE/SEI 74.

FRP / GFRP Channel Profile — Technical Data SheetSection property formulas for channels | Page 4 of 5

Section formulas for composite channel

1. Cross-section area and weight
A = 2 b tf + (h − 2tf) tw ,   w = ρ A

152×42×6.4: A = 2 × 42 × 6.4 + 139.2 × 6.4 ≈ 1428 mm²; w ≈ 2.64 kg/m

2. Moment of inertia about the strong axis
Ix = b h³ − (b − tw)(h − 2tf)³12 ,   Wx = 2 Ixh

152×42×6.4: Ix ≈ 4.29×10⁶ mm⁴ and Wx ≈ 5.64×10⁴ mm³

3. Centroid and weak-axis moment of inertia
x̄ = Σ Ai xiA ,   Iy = Σ ( hi bi³12 + Ai (xi − x̄)² )

152×42×6.4: x̄ ≈ 9.9 mm from the back of the web; Iy ≈ 1.88×10⁵ mm⁴ (about 4% of Ix)

4. Torsion constant of an open section
J ≈ 2 b tf³ + (h − 2tf) tw³3

152×42×6.4: J ≈ 1.95×10⁴ mm⁴; grows with the cube of thickness (thickness 9.5 → 6.2×10⁴)

5. Shear-centre location (thin-walled section)
e0 = b′² · h′² · tf4 Ix ,   b′ = b − tw/2 ,   h′ = h − tf

152×42×6.4: b′ = 38.8, h′ = 145.6 → e0 = 38.8² × 145.6² × 6.4 / (4 × 4.29×10⁶) ≈ 11.9 mm behind the web centreline. To avoid torsion, the line of action of the load must pass through this point.

6. Warping constant
Cw = tf b′³ h′² (3 b′ tf + 2 h′ tw)12 (6 b′ tf + h′ tw)

152×42×6.4: Cw ≈ 7.11×10⁸ mm⁶; the section’s resistance to warping under torsion and an input to the lateral-torsional buckling formula (Formula 8)

7. Back-to-back double channel
Iy,2 = 2 [ Iy + A ( x̄ + g2 )² ] ,   Ix,2 = 2 Ix

Two 152×42×6.4 channels with gap g = 10 mm: Iy,2 ≈ 1.01×10⁶ mm⁴ (about 2.7 times the sum of Iy of two single channels); shear centre on the axis of symmetry and no load-induced torsion.

Section design note: in composite channel, Iy is only 4 to 5 percent of Ix and the torsion constant J is very small; these two numbers, not Ix, govern the capacity of an unbraced beam. Increasing thickness from 6.4 to 9.5 mm more than triples J and, for FRP channel beams with limited lateral restraint, is more effective than increasing web height.

FRP / GFRP Channel Profile — Technical Data SheetBeam design, connections and fabrication | Page 5 of 5

Beam design with composite channel

8. Critical moment for lateral-torsional buckling (classical approximation)
Mcr = πLb √( E Iy · G J ) · √( 1 + π² E CwG J Lb² ) ,   Ma = min(Mcr, σu Wx)FS
Example — FRP channel beam 152×42×6.4, E = 23 GPa, G = 3 GPa, FS = 2.5: Section strength: σu Wx = 240 × 5.64×10⁴ ≈ 13.5 kN·m Unbraced Lb = 2.0 m: Mcr ≈ 1.03 kN·m → Ma ≈ 0.41 kN·m → qa ≈ 0.82 kN/m Braced every Lb = 0.5 m: Mcr ≈ 11.0 kN·m → ≈ 10× higher capacity Without lateral restraint, a composite channel beam reaches only about 8% of its section capacity. Fixing FRP grating or decking to the compression flange at close spacing, or lateral bracing every 500 mm, brings capacity close to the section strength. The relation is for load at the shear centre; load on the top flange reduces Mcr.
9. Beam deflection (bending + shear)
δ = 5 q L⁴384 E Ix + q L²8 G Aw

152×42×6.4, L = 2 m, q = 1 kN/m, Aw = tw(h − 2tf) ≈ 891 mm²: δ ≈ 2.11 + 0.19 ≈ 2.3 mm (L/870)

10. Web crushing at supports
Ra = σc,T · tw · (N + 2.5 tf)FS

σc,T ≈ 70 MPa, N = 50 mm bearing, FS = 3: Ra = 70 × 6.4 × 66 / 3 ≈ 9.9 kN (simple estimate; use a web stiffener plate for higher loads)

11. Bolted web connection capacity
Pbr = n d tw σbrFS ;   e1 ≥ 2d, p ≥ 4d

3 M12 bolts in a 6.4 mm web, σbr = 150 MPa, FS = 3: Pbr ≈ 11.5 kN

12. Thermal expansion of the beam
ΔL = α · L · ΔT

6 m channel, α = 9×10⁻⁶, ΔT = 40 °C → ΔL ≈ 2.2 mm; compatible with steel and concrete structures

Fabrication guide for composite channel

  1. Orientation: install the channel with the web vertical and flanges horizontal; transfer load as far as possible through the back of the web near the shear centre.
  2. Lateral restraint: restrain the compression flange of FRP channel beams with grating, decking or bracing at close spacing.
  3. Cutting and drilling: use diamond or carbide saws and drills; hole diameter 1 to 1.5 mm larger than the bolt.
  4. Sealing: coat cut surfaces and holes with compatible resin.
  5. Connection: composite clip angles and stainless or FRP bolts with wide washers; in critical joints, structural adhesive together with bolts.
  6. Double channel: fix two channels back-to-back with spacers and stitch bolts every 400 to 600 mm.
Request a quote for FRP channel: send section size, length and number of bars, colour, resin type and the cutting and drilling drawing.
Nabak Saze Gostar | nabakcomposite.com | +98 21 4881 2124 | Mobile +98 912 396 3078 | Instagram @nabak.composite

Disclaimer: The information in this data sheet is based on general, typical data of the FRP and GFRP composites industry and the EN 13706 standard, and is intended as guidance only. Examples are for illustration; structural design must be carried out by a qualified engineer. NABAK COMPOSITE reserves the right to change technical specifications without notice.